產(chǎn)品[
礦用移動類阻燃橡套軟電纜
]資料
如果您對該產(chǎn)品感興趣的話,可以
產(chǎn)品名稱:
礦用移動類阻燃橡套軟電纜
產(chǎn)品型號:
MYQ,MY,MYP,MZ,MC,MCP
產(chǎn)品展商:
紅旗
關(guān)注指數(shù):2345
產(chǎn)品文檔:
無相關(guān)文檔
簡單介紹
產(chǎn)品用途:產(chǎn)品供煤礦移動電器設(shè)備及采掘機(jī)械配套用。
Scope of application:The product necessary uses for the coal mine migration electric appliance equipment and the excavation machinery
執(zhí)行標(biāo)準(zhǔn) Standards implemented: MT 818-200
礦用移動類阻燃橡套軟電纜
的詳細(xì)介紹
|
|
Mobile fire retardant rubber soft cables for mines
產(chǎn)品用途:產(chǎn)品供煤礦移動電器設(shè)備及采掘機(jī)械配套用。
Scope of application:The product necessary uses for the coal mine migration electric appliance equipment and the excavation machinery
執(zhí)行標(biāo)準(zhǔn) Standards implemented: MT 818-2009
|
|
型號名稱 Model descriptions
型 號
Model
|
名 稱
Descriptions
|
MY
|
煤礦用移動橡套軟電纜
Mobile rubber soft cables for mines
|
MYQ
|
煤礦用移動輕型橡套軟電纜
Mobile light type rubber soft cables for mines
|
MYP
|
煤礦用移動屏蔽橡套軟電纜
Mobile shielded rubber soft cables for mines
|
MC
|
采煤機(jī)橡套軟電纜
Rubber soft cables for coal cutter in mines
|
MCP
|
采煤機(jī)屏蔽橡套軟電纜
Shielded rubber soft cables for coal cutter in mines
|
MZ
|
煤礦用電鉆橡套電纜
Electric drill rubber cables for mines
|
MZP
|
煤礦用電鉆屏蔽橡套電纜
Electric drill shielded rubber cables for mines
|
使用特性
Service characteristics
型 號
Model
|
MYQ MZ MZP MY MYP MC MCP
|
額定電壓
U0/U Rated voltage
|
0.3/0.5kv 0.38/0.66kv 0.66/1.14kv
|
電纜長期允許工作溫度
Long-term service temperature of the cable conductor
|
65℃
|
電纜的*小彎曲半徑
Minimun bending radius
|
6D
|
電纜規(guī)格 Specifications
型 號
Model
|
芯 數(shù)
Core number
|
額定電壓 KV
Rated voltage
|
標(biāo)稱截面mm2
Nominal sectional
|
動力線芯
Core for power
|
地線芯
Core for ground
|
控制線芯
Pilot wire core
|
MY
|
1
|
0.38/0.66
|
50-150
|
-
|
-
|
3+1
|
3x4-3x70
|
1x4-1x25
|
-
|
MZ MZP
|
3+1、3+1+1
|
0.3/0.5
|
3X2.5-3X4
|
1X2.5-1X4
|
1X2.5-1X4
|
MYQ
|
2、3、4、7、12
|
0.3/0.5
|
1.0-2.5
|
-
|
-
|
3+1
|
3X1.0-3X2.5
|
1X0.75-1X1.5
|
MC
|
3+1+3
|
0.38/0.66
|
3x16-3x50
|
1x4-1x10
|
3x2.5-3x4
|
MCP
|
3+1+3
|
0.38/0.66
|
3x16-3x50
|
1x4-1x10
|
3x2.5-3x4
|
0.66/1.14
|
3x35-3x95
|
1x6-1x25
|
MYP
|
3+1
|
0.38/0.66
|
3x4-3x70
|
1x4-1x25
|
-
|
0.66/1.14
|
3x10-3x95
|
1x10-1x25
|
電纜主要技術(shù)性能
Major technical performances
1、 電纜導(dǎo)體直流電阻
DC resistance of the conductor
型 號
Model
|
標(biāo)稱截面
Nominal sectional
(mm2)
|
200C時導(dǎo)體直流電阻(≤Ω/Km)
DC resistance of the conductor at 20℃
|
型 號
Model
|
標(biāo)稱截面
Nominal sectional
(mm2)
|
200C時導(dǎo)體直流電阻(≤Ω/Km)
DC resistance of the conductor at 20℃
|
不鍍錫
Untinned
|
鍍錫
Tinned
|
不鍍錫
Untinned
|
鍍錫
Tinned
|
MYQ
|
1.0
|
19.5
|
20.0
|
MY
MYP
|
10
|
1.91
|
1.95
|
1.5
|
13.3
|
13.7
|
16
|
1.21
|
1.24
|
2.5
|
7.98
|
8.21
|
25
|
0.780
|
0.795
|
MZ
MZP
|
2.5
|
-
|
8.82
|
35
|
0.554
|
0.565
|
4
|
-
|
5.39
|
50
|
0.386
|
0.393
|
MC
MCP
|
4
|
-
|
5.09
|
70
|
0.272
|
0.277
|
6
|
-
|
3.39
|
95
|
0.206
|
0.210
|
10
|
-
|
1.95
|
120
|
0.161
|
0.164
|
16
|
-
|
1.24
|
150
|
0.129
|
0.132
|
25
|
-
|
0.795
|
185
|
0.106
|
0.108
|
35
|
-
|
0.565
|
240
|
0.0801
|
0.0817
|
50
|
-
|
0.393
|
300
|
0.0641
|
0.0654
|
MY
MYP
|
4
|
4.95
|
5.09
|
400
|
0.0485
|
0.0495
|
6
|
3.30
|
3.39
|
-
|
-
|
-
|
2、 電纜的絕緣電阻 Dielectric resistance
型 號
Model
|
動力線芯標(biāo)稱截面mm2
Core for power nominal sectional
|
20℃時絕緣電阻
(≥MΩ Km)
Dielectric resistance at 20℃
|
型 號
Model
|
動力線芯標(biāo)稱截面mm2
Core for power nominal sectional
|
20℃時絕緣電阻(≥MΩ Km)
Dielectric resistance at 20℃
|
MYQ
|
1.0
|
160
|
MY
MYP
|
10
|
160
|
1.5
|
160
|
16
|
120
|
2.5
|
160
|
25
|
120
|
MZ
MZP
|
2.5
|
160
|
35
|
100
|
4
|
160
|
50
|
100
|
MC
MCP
|
16
|
120
|
70
|
80
|
25
|
120
|
95
|
80
|
35
|
100
|
120
|
50
|
50
|
100
|
150
|
50
|
70
|
80
|
185
|
50
|
95
|
80
|
240
|
50
|
限制線芯Control core
|
100
|
300
|
50
|
MY
MYP
|
4
|
200
|
400
|
50
|
6
|
180
|
-
|
-
|
3、電纜其它主要技術(shù)性能 Other major technical performances
(型 號 Model:MY MYP MYQ MC MCP MZ MZP)
序 號
Serial number
|
項 目
Items
|
技術(shù)性能
Technical performances
|
1
|
線芯直流電阻(≤Ω/Km)
Core DC resistance
|
見上表
See above table
|
2
|
絕緣電阻(≥MΩ Km)
Insulating resistance
|
見上表
See above table
|
3
|
5min工頻電壓試驗
5min power frequency voltage experiment
|
0.66/1.14
|
3.7KV工頻電壓絕緣不擊穿
3.7KV power frequency voltage insulation does not penetrate
|
0.38/0.66
|
3KV工頻電壓絕緣不擊穿
3KV power frequency voltage insulation does not penetrate
|
0.3/0.5
|
2KV工頻電壓絕緣不擊穿
2KV power frequency voltage insulation does not penetrate
|
控制線芯Control core
|
1.5KV工頻電壓絕緣不擊穿
1.5KV power frequency voltage insulation does not penetrate
|
4
|
熱延伸試驗
The heat extends the experiment
|
≤175%
|
5
|
單根垂直燃燒試驗
Single wire burning test
|
MT386
|
6
|
成束燃燒試驗
Group burning test
|
*大線芯截面積在50mm2及以上時 符合A類成束燃燒試驗要求
Max. core sectional area more than 50mm2 conforms A kind group burning test
|
7
|
*大線芯截面積在50mm2及以下時 符合B類成束燃燒試驗要求
Max. core sectional area more than 50mm2 conforms B kind group burning test
|
|
|
|